<?xml version="1.0" encoding="UTF-8"?>
<doi_batch version="4.4.2" xmlns="http://www.crossref.org/schema/4.4.2" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:jats="http://www.ncbi.nlm.nih.gov/JATS1" xsi:schemaLocation="http://www.crossref.org/schema/4.4.2 http://www.crossref.org/schema/deposit/crossref4.4.2.xsd">
<head>
<doi_batch_id>26224ab4184a136f282-42a7</doi_batch_id>
<timestamp>20230107064114421</timestamp>
<depositor>
  <depositor_name>beie:beie</depositor_name> 
  <email_address>director@blueeyesintelligence.org</email_address>
</depositor>
<registrant>WEB-FORM</registrant> 
</head>
<body>
<journal>
<journal_metadata>   <full_title>International Journal of Innovative Technology and Exploring Engineering</full_title>   <abbrev_title>IJITEE</abbrev_title>   <issn media_type='electronic'>22783075</issn>   <doi_data>     <doi>10.35940/ijitee</doi>     <resource>https://www.ijitee.org/</resource>   </doi_data> </journal_metadata> <journal_issue>  <publication_date media_type='online'>     <month>01</month>     <day>30</day>     <year>2023</year>   </publication_date>   <journal_volume>     <volume>12</volume>   </journal_volume>   <issue>2</issue> </journal_issue><!-- ============== --> <journal_article publication_type='full_text'>   <titles>     <title>Multi Wear Response Optimization of Ti-6Al-7Nb Biomedical Alloy</title>   </titles>   <contributors>      <organization sequence='first' contributor_role='author'>Department of Mechanical Engineering, Rajeev Gandhi Memorial College of Engineering and Technology, Nandyal (A.P), India. E</organization>    <person_name sequence='first' contributor_role='author'>      <given_name>Syed Altaf</given_name>      <surname>Hussain</surname>      <ORCID>https://orcid.org/0000-0002-9548-679X</ORCID>    </person_name>    <person_name sequence='additional' contributor_role='author'>       <given_name>Uprendra</given_name>       <surname>Rajak</surname>       <ORCID>https://orcid.org/0000-0002-3884-8758</ORCID>     </person_name>     <organization sequence='additional' contributor_role='author'>Department of Mechanical Engineering, Rajeev Gandhi Memorial College of Engineering and Technology, Nandyal (A.P), India.</organization>     <person_name sequence='additional' contributor_role='author'>       <given_name>Subhahan Basha</given_name>       <surname>C</surname>       <ORCID>https://orcid.org/0000-0002-3531-5665</ORCID>     </person_name>     <organization sequence='additional' contributor_role='author'>Research Scholar, Jawaharlal Nehru Technological University Anantapur, Anantapur (A.P), India.</organization>   </contributors>    <jats:abstract xml:lang='en'>         <jats:p>Titanium-Niobium (Ti-Nb) based alloys are predominantly used as an implant material within the Bio-medical field due to their unique characteristics such as non-toxicity, better Osseo-integration, high resistance to corrosion, high strength to weight quantitative relation and biocompatibility. This paper proposes to optimize the control parameters for multi-response optimization of Ti-6Al-7Nb bio-medical alloy based Grey Relational Analysis combined with the Taguchi approach. Wear rate (WR), coefficient of friction (COF), and frictional force were the response characteristics studied (FF). The Taguchi methodology is used in conjunction with the grey interpersonal evaluation as a performance index to determine the best set of control parameters. Applied Load, Rotational Speed, and Time were the control parameters evaluated. Experimentations are designed using L9 Taguchi's orthogonal array and carried out on a pin-on-disc setup in agreement by ASTM G99. The experimental outcomes display that the applied load has the greatest impact on the Ti-6Al-7Nb bio-medical alloy's various wear characteristics. This approach has been successfully rummage-sale to recover the wear response of Ti-6Al-7Nb bio-medical alloy.</jats:p>     </jats:abstract>  <publication_date media_type='online'>     <month>01</month>     <day>30</day>     <year>2023</year>   </publication_date>   <pages>     <first_page>19</first_page>     <last_page>25</last_page>   </pages>   <crossmark>     <crossmark_version>CC BY-NC-ND 4.0</crossmark_version>     <crossmark_policy>10.35940/BEIESP.CrossMarkPolicy</crossmark_policy>     <crossmark_domains>       <crossmark_domain>          <domain>www.ijitee.org</domain>       </crossmark_domain>     </crossmark_domains>     <crossmark_domain_exclusive>true</crossmark_domain_exclusive>     <custom_metadata>       <assertion explanation='Funding' group_label='Funding' group_name='Funding' name='Declaration' order='0'>Not receive.</assertion>       <assertion explanation='Conflicts of Interest' group_label='Conflicts of Interest' group_name='Conflicts-of-Interest' name='Declaration' order='1'>No conflicts of interest to the best of our knowledge.</assertion>       <assertion explanation='Ethical Approval and Consent to Participate' group_label='Ethical Approval and Consent to Participate' group_name='Ethical-Approval-and-Consent-to-Participate' name='Declaration' order='2'>No, the article does not require ethical approval and consent to participate with evidence.</assertion>       <assertion explanation='Availability of Data and Material' group_label='Availability of Data and Material' group_name='Availability-of-Data-and-Material' name='Declaration' order='3'>Not relevant.</assertion>       <assertion explanation='Authors Contributions' group_label='Authors Contributions' group_name='Authors-Contributions' name='Declaration' order='4'>All authors have equal participation in this article.</assertion>     </custom_metadata>   </crossmark>   <doi_data>     <doi>10.35940/ijitee.B9409.0112223</doi>     <resource>https://www.ijitee.org/portfolio-item/B94090112223/</resource>   </doi_data> </journal_article>
</journal>
</body>
</doi_batch>
