Thermal Insulation and R- Value Analysis for Wall Insulated with PCM
K. S. Dhaya Chandhran1, M. Jothilakshmi2, L. Chandhrkanthamma3, A. Mohan4

1K. S. Dhaya Chandhran, Department of Civil Engineering, Easwari Engineering College, Ramapuram, Chennai (Tamil Nadu), India.

2M. Jothilakshmi, Department of Civil Engineering, Easwari Engineering College, Ramapuram, Chennai (Tamil Nadu), India.

3L. Chandhrkanthamma, Department of Civil Engineering, Easwari Engineering College, Ramapuram, Chennai (Tamil Nadu), India.

4A. Mohan, Department of Civil Engineering, Easwari Engineering College, Ramapuram, Chennai (Tamil Nadu), India.

Manuscript received on 04 October 2019 | Revised Manuscript received on 18 October 2019 | Manuscript Published on 26 December 2019 | PP: 11-16 | Volume-8 Issue-12S October 2019 | Retrieval Number: L101310812S19/2019©BEIESP | DOI: 10.35940/ijitee.L1013.10812S19

Open Access | Editorial and Publishing Policies | Cite | Mendeley | Indexing and Abstracting
© The Authors. Blue Eyes Intelligence Engineering and Sciences Publication (BEIESP). This is an open-access article under the CC-BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)

Abstract: At present all the Indians are depending on non-renewable energy for electricity for house needs. The nature is exploited by this Nonrenewable energy, it scarce fossil fuel source and destroys mother nature. The Air conditioners are devices which is used to reduce the indoor temperature and increases the comfort level. This devices produces greenhouse gases and increasing day by day, which obviously increases Global warming. The medical experts are insisting not to use and expose more to Air conditioners as it stimulates health issues. In order to overcome these problems, an alternate solution to be found and implementing a new method of construction and materials. This is the new attempt by executing a system of cavity wall in a framed structure with circulation of liquid and air in the cavity by embedding the fluted sheets in the exterior walls of the building. The advantage of this system is reducing the thermal conductivity from outside and to reduce the consumption of electricity for air conditioning devices and increases the sustainability of natural sources. Finally the constant-R (Thermal resistivity) value is arrived for composite materials with water.

Keywords: Cavity Wall, Fluted Sheet, Global Warming, Green Building, Hygrometer, PCM, Thermal Envelope.
Scope of the Article: Structural Reliability Analysis